smartwater

Dissolved solids209mg/Llab test
pH6.3lab test
Calcium70.6mg/Lstudy
Magnesium5.6mg/Lstudy
Sodium0.16mg/Lstudy
Hardness199mg/L as CaCO₃calculated

On the lists: Water for coffee #17 · Espresso machines #94 · Low sodium · pH of every water · Dissolved solids

For coffee

Outside the SCA's ranges

  • Calcium hardness 176 target 50–175 mg/L just over the top
  • Alkalinity 9 target 40–70 mg/L 23% of the minimum
  • pH 6.3 target 6–8 in range

#17 of 113 on the list, closest first.

Against the Specialty Coffee Association's Standard 102-2024. How we rate

For espresso machines

Scale or corrosion risk

  • Hardness 199 target 70–100 mg/L 2.0× the top
  • Alkalinity 9 target 40–75 mg/L 23% of the minimum
  • Dissolved solids 209 target 90–150 mg/L 1.4× the top
  • Chloride 125 target under 30 mg/L 4.2× the top
  • pH 6.3 target 6.5–8 0.2 below

Langelier index at 93 °C: -1.33 (La Marzocco aims for +0.1 to +0.7: higher leaves more scale, and below zero the water tends to be corrosive).

#94 of 111 on the list, closest first.

Against La Marzocco's and Lelit's water specifications. Follow your own machine's manual. How we rate

For tea

Very hard water

Very hard water tends to make darker, cloudier tea and more of the film on black tea.

There's no official water standard for tea, so this is the USGS hardness class. Waters for tea

Minerals at a glance

  • Low mineral content (dissolved solids 500 mg/L or less)
  • Under 20 mg/L of sodium: the EU's level for "suitable for a low-sodium diet"

EU mineral water label levels, for comparison only. Dissolved solids of every water

Minerals and where each value comes from

mg/L is the same as parts per million (ppm) for water. "ND" means the lab didn't detect it. Each value is from the best source that reports it: the brand's own report first, then its website, an archived copy of an older report, a lab test or a study. More on sources

MeasureValueUnitSource
Total dissolved solids209mg/LLab test of one bottle, 2017, by NSF Erdmann Analytics lab test
pH6.3Lab test of one bottle, 2017, by NSF Erdmann Analytics lab test
Calcium70.6mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Magnesium5.6mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Sodium0.16mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Potassium5.3mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Bicarbonate11mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Total alkalinity9mg/L as CaCO₃Calculated from the bicarbonate above
Total hardness199mg/L as CaCO₃Calculated from the calcium and magnesium above
Calcium hardness176mg/L as CaCO₃Calculated from the calcium above
Sulfate<0.5mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Chloride125mg/LLab test of one bottle, 2017, by NSF Erdmann Analytics lab test
Conductivity449µS/cmLab test of one bottle, 2017, by NSF Erdmann Analytics lab test

One bottle (GLACEAU smartwater, vapour distilled water) tested by NSF Erdmann Analytics GmbH, Germany (report 17W1636, 2017-11-22) for Valvis Holding, the owner of Aqua Carpatica, which published it. TDS is calculated from the ions.

Lab tests here are of a single bottle bought in 2017 or 2018, tested by NSF Erdmann Analytics in Germany and published by Aqua Carpatica, a competing brand. A brand's own report always takes precedence where it gives the same mineral.

Waters with similar hardness and alkalinity

Sources