Aquafina

Dissolved solidsNDmg/Lbrand report
pH5.6lab test
Calcium33.6mg/Lstudy
Magnesium11.7mg/Lstudy
Sodium1.8mg/Lstudy
Hardness132mg/L as CaCO₃calculated

On the lists: Water for coffee #35 · Espresso machines #64 · Low sodium · pH of every water · Dissolved solids · Water for tea · Fluoride

For coffee

Outside the SCA's ranges

  • Calcium hardness 83.9 target 50–175 mg/L in range
  • Alkalinity 4.1 target 40–70 mg/L 10% of the minimum
  • pH 5.6 target 6–8 0.4 below

#35 of 113 on the list, closest first.

Against the Specialty Coffee Association's Standard 102-2024. How we rate

For espresso machines

Scale or corrosion risk

  • Hardness 132 target 70–100 mg/L 1.3× the top
  • Alkalinity 4.1 target 40–75 mg/L 10% of the minimum
  • Dissolved solids 0 target 90–150 mg/L almost none
  • Chloride 0.33 target under 30 mg/L in range
  • pH 5.6 target 6.5–8 0.9 below

#64 of 111 on the list, closest first.

Against La Marzocco's and Lelit's water specifications. Follow your own machine's manual. How we rate

For tea

Hard water

Hard water tends to make darker, cloudier tea and more of the film on black tea.

There's no official water standard for tea, so this is the USGS hardness class. Waters for tea

Minerals at a glance

  • Very low mineral content (dissolved solids 50 mg/L or less)
  • Under 20 mg/L of sodium: the EU's level for "suitable for a low-sodium diet"

EU mineral water label levels, for comparison only. Dissolved solids of every water

Minerals and where each value comes from

mg/L is the same as parts per million (ppm) for water. "ND" means the lab didn't detect it. Each value is from the best source that reports it: the brand's own report first, then its website, an archived copy of an older report, a lab test or a study. More on sources

MeasureValueUnitSource
Total dissolved solidsNDmg/LThe brand's water quality report, 2025 brand report
pH5.6Lab test of one bottle, 2017, by NSF Erdmann Analytics lab test
Calcium33.6mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Magnesium11.7mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Sodium1.8mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Potassium0.5mg/LLabel values in Stoots et al. 2021 (Journal of Clinical Medicine) study
Bicarbonate5mg/LLab test of one bottle, 2017, by NSF Erdmann Analytics lab test
Total alkalinity4mg/L as CaCO₃Calculated from the bicarbonate above
Total hardness132mg/L as CaCO₃Calculated from the calcium and magnesium above
Calcium hardness84mg/L as CaCO₃Calculated from the calcium above
Sulfate0–0.49mg/LThe brand's water quality report, 2025 brand report
Chloride0–0.65mg/LThe brand's water quality report, 2025 brand report
FluorideNDmg/LThe brand's water quality report, 2025 brand report
Nitrate (as nitrogen)0–0.26mg/LThe brand's report, 2019 (copy at gwern.net) archived copy
Conductivity5µS/cmLab test of one bottle, 2017, by NSF Erdmann Analytics lab test

One bottle (AQUAFINA, pure water) tested by NSF Erdmann Analytics GmbH, Germany (report 17W1664, 2017-11-29) for Valvis Holding, the owner of Aqua Carpatica, which published it. TDS is calculated from the ions.

Lab tests here are of a single bottle bought in 2017 or 2018, tested by NSF Erdmann Analytics in Germany and published by Aqua Carpatica, a competing brand. A brand's own report always takes precedence where it gives the same mineral.

Waters with similar hardness and alkalinity

Sources