Volvic

Dissolved solids108mg/Llab test
pH6.5lab test
Calcium13mg/Lbrand website
Magnesium9mg/Lbrand website
Sodium12mg/Lbrand website
Hardness70mg/L as CaCO₃calculated

On the lists: Water for coffee #8 · Espresso machines #1 · Low sodium · pH of every water · Dissolved solids · Water for tea · Fluoride

For coffee

Outside the SCA's ranges

  • Calcium hardness 32.5 target 50–175 mg/L 65% of the minimum
  • Alkalinity 65.6 target 40–70 mg/L in range
  • pH 6.5 target 6–8 in range

#8 of 113 on the list, closest first.

Against the Specialty Coffee Association's Standard 102-2024. How we rate

For espresso machines

Very soft: check your machine's manual

  • Hardness 69.5 target 70–100 mg/L just under the minimum
  • Alkalinity 65.6 target 40–75 mg/L in range
  • Dissolved solids 108 target 90–150 mg/L in range
  • Chloride 16 target under 30 mg/L in range
  • pH 6.5 target 6.5–8 in range

Langelier index at 93 °C: -0.97 (La Marzocco aims for +0.1 to +0.7: higher leaves more scale, and below zero the water tends to be corrosive).

#1 of 111 on the list, closest first.

Against La Marzocco's and Lelit's water specifications. Follow your own machine's manual. How we rate

For tea

Moderately hard water

Moderately hard: between soft and hard water in how it brews tea.

There's no official water standard for tea, so this is the USGS hardness class. Waters for tea

Minerals at a glance

  • Low mineral content (dissolved solids 500 mg/L or less)
  • Under 20 mg/L of sodium: the EU's level for "suitable for a low-sodium diet"

EU mineral water label levels, for comparison only. Dissolved solids of every water

Minerals and where each value comes from

mg/L is the same as parts per million (ppm) for water. "ND" means the lab didn't detect it. Each value is from the best source that reports it: the brand's own report first, then its website, an archived copy of an older report, a lab test or a study. More on sources

MeasureValueUnitSource
Total dissolved solids108mg/LLab test of one bottle, 2017, by NSF Erdmann Analytics lab test
pH6.5Lab test of one bottle, 2017, by NSF Erdmann Analytics lab test
Calcium13mg/LThe brand's website brand website
Magnesium9mg/LThe brand's website brand website
Sodium12mg/LThe brand's website brand website
Potassium7mg/LThe brand's website brand website
Bicarbonate80mg/LThe brand's website brand website
Total alkalinity66mg/L as CaCO₃Calculated from the bicarbonate above
Total hardness70mg/L as CaCO₃Calculated from the calcium and magnesium above
Calcium hardness32mg/L as CaCO₃Calculated from the calcium above
Sulfate9mg/LThe brand's website brand website
Chloride16mg/LThe brand's website brand website
Fluoride0.34mg/LUSDA National Fluoride Database of Selected Beverages and Foods (2005) dataset
Nitrate (as nitrogen)7.7mg/LThe brand's website brand website
Silica31mg/LThe brand's website brand website
Conductivity203µS/cmLab test of one bottle, 2017, by NSF Erdmann Analytics lab test

One bottle (Volvic, NATURAL MINERAL WATER) tested by NSF Erdmann Analytics GmbH, Germany (report 17W1584, 2017-11-23) for Valvis Holding, the owner of Aqua Carpatica, which published it. TDS is calculated from the ions.

Lab tests here are of a single bottle bought in 2017 or 2018, tested by NSF Erdmann Analytics in Germany and published by Aqua Carpatica, a competing brand. A brand's own report always takes precedence where it gives the same mineral.

Waters with similar hardness and alkalinity

Sources